When it doesn's start or start but immediately
stop
|
a. Power Failure b. Large Discrepancy
between power source and voltage c.
Significant voltage drop d. Motor phase
malfunction e. Electric circuit connection f.
Faulty control circuit connection g.
Blown fuse h. Faulty magnetic switch i.
Short circuit breaker is functioning j.
Foreign matter clogging pump k. Motor
burn out
|
a~c. Contact electric power company and
devise counter measures d. Inspection
connection and magnetic switch e. Inspect
electric circuit f. Correct wiring g.
Replace with correct type fuse h. Replace
with correct type magnetic switch i.
Repair location of short circuit j. Remove
foreign matter k. Repair or replace
|
|
When it works but soon stops
|
a, Prolonged dry operation has activated
motor protector and caused pump to stop b.
High liquid temperature has activated motor
protector and caused pump to stop
|
a, Raise stop water level
b. Lower liquid temperature
|
|
When it works but capacity is not adequate
|
a, Reverse Rotation b, Significant
drop in voltage c, Operating 60HZ pump
on 50HZ d, Discharge head is high e,
Large piping loss f, Low operating water
level causes air suction g, Leak from
discharge piping h, Clogged discharge
piping i, Foreign matter in suction j,
Foreign mater clogging pump k, worn out
impeller
|
a, Correct rotation b, Contact electric
power company and devise counter measures c,
Check name plate d, Recalculate and adjust e,
Recalculate and adjust f, Raise water
level or lower pump g, Inspect, repair h,
remove foreign matter i, Remove foreign
matter j, Disassemble and remove foreign
matter k, Replace impeller
|